英语翻译List of ConstantsConstantno.DedicatedindicatorDescription Setting range Factory settingn01 Constant write-inhibit selection/constant initialization0,1,8,9 1n02 Operation mode selection 0 to 5 0n03 Interruption mode selection 0,1 0n04 Forw

来源:学生作业帮助网 编辑:作业帮 时间:2024/04/29 15:41:41
英语翻译List of ConstantsConstantno.DedicatedindicatorDescription Setting range Factory settingn01 Constant write-inhibit selection/constant initialization0,1,8,9 1n02 Operation mode selection 0 to 5 0n03 Interruption mode selection 0,1 0n04 Forw

英语翻译List of ConstantsConstantno.DedicatedindicatorDescription Setting range Factory settingn01 Constant write-inhibit selection/constant initialization0,1,8,9 1n02 Operation mode selection 0 to 5 0n03 Interruption mode selection 0,1 0n04 Forw
英语翻译
List of Constants
Constant
no.
Dedicated
indicator
Description Setting range Factory setting
n01 Constant write-inhibit selection/
constant initialization
0,1,8,9 1
n02 Operation mode selection 0 to 5 0
n03 Interruption mode selection 0,1 0
n04 Forward/reverse rotation
selection
For,rEv For
n06 Multi-function input selection
0 to 4 1
n09 Multi-function output selection
0,1,2 1
n11 Frequency reference 1 0.0 to 400 6.0 (Hz)
n12 Frequency reference 2 0.0 to 400 0.0 (Hz)
n20 Acceleration time 0.0 to 999 10.0 (seconds)
n21 Deceleration time 0.0 to 999 10.0 (seconds)
n24 Maximum frequency 50.0 to 400 60.0 (Hz)
n25 Maximum voltage 1 to 255
(see note 1)
200 (V)
(see note 1)
n26 Maximum voltage frequency 1.6 to 400 60.0 (Hz)
n31 Electronic thermal reference
current
0.0 to see note 2 See note 2
n33 Stall prevention during deceleration
0,1 0
n36 Operation after recovery
from power interruption
0,1,2 0
n37 Carrier frequency 1,2,3,4
(see note 3)
4
(see note 4)
n39 Frequency reference gain 0.10 to 2.55 1.00
n40 Frequency reference bias –99 to 99 0 (%)
n61 Stop Key selection 0,1 0
n64 Operator’s frequency setting
method
0,1 0
n68 Error history (Display only)

英语翻译List of ConstantsConstantno.DedicatedindicatorDescription Setting range Factory settingn01 Constant write-inhibit selection/constant initialization0,1,8,9 1n02 Operation mode selection 0 to 5 0n03 Interruption mode selection 0,1 0n04 Forw
List of Constants 常量表
Constant 常量
no.号码
Dedicated 专
indicator 指标
Description Setting range Factory setting 设置成出厂
n01 Constant write-inhibit selection/
constant initialization 常量设置禁止/常量初始设置
0,1,8,9 1
n02 Operation mode selection 0 to 5 0 操作模式选择
n03 Interruption mode selection 0,1 0中断模式选择
n04 Forward/reverse rotation 正反转,转换
selection选择
For,rEv For
n06 Multi-function input selection多功能输入选择
0 to 4 1
n09 Multi-function output selection多功能输出选择
0,1,2 1
n11 Frequency reference 1 0.0 to 400 6.0 (Hz)频率参照、给定
n12 Frequency reference 2 0.0 to 400 0.0 (Hz)
n20 Acceleration time 0.0 to 999 10.0 (seconds)加速时间
n21 Deceleration time 0.0 to 999 10.0 (seconds)减速时间
n24 Maximum frequency 50.0 to 400 60.0 (Hz)设置变频器输出的最大频率
n25 Maximum voltage 1 to 255设置变频器输出最大电压(see note 1)
200 (V)
(see note 1)
n26 Maximum voltage frequency 1.6 to 400 设置最大电压时允许的输出频率60.0 (Hz)
n31 Electronic thermal reference (应该是设定升速时的电流最大升高数,达到这个数变频器就会减少频率增加速度以防止超电流跳)
current
0.0 to see note 2 See note 2
n33 Stall prevention during deceleration应该是设置减速时的参数以便减速时防止过电压跳
0,1 0
n36 Operation after recovery停电时的操作方式(是否允许重新起动及飞车起动)主要用于短时间停电后的及时起动以便不影响设备运行(比如送水)
from power interruption
0,1,2 0
n37 Carrier frequency 1,2,3,4载波频率
(see note 3)
4
(see note 4)
n39 Frequency reference gain 0.10 to 2.55 1.00频率增益
n40 Frequency reference bias –99 to 99 0 (%)频率斜坡
n61 Stop Key selection 0,1 0停车选择
n64 Operator’s frequency setting
method操作频率结定
0,1 0
n68 Error history (Display only) 错误(历史)记录